Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - infinite spa CHAMPION Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für CHAMPION:
Inhaltsverzeichnis

Werbung

4
Maintenance
4.5 Cleaning the SPA
The cleaning of the SPA does not require any special care or maintenance. Remove dirt with soap. water, a damp cloth and a soft brush, if
required. Never use hard brushes or abrasive cleaning and scouring products.
4.6 Winter storage
1. Drain all the water from the SPA.
2. Remove the filter cartridge
3. Clean and dry the SPA and attachments
4. Expel all the air from the SPA
5. Loosely fold up the SPA, avoiding sharp corners to prevent damage
6. Store the SPA in a dry, frost-free place.
8. The original packaging can be used for storage.
CAUTION:
• Plastic can become brittle and fragile when it is exposed to sub-zero temperatures.
• Freezing can severely damage the SPA. Improper winter storage may invalidate the warranty.
• Ubbink Garden B.V. cannot accept liability for damage to the SPA and its components resulting from the use of antifreeze agents.
5

Troubleshooting

Here you will find useful tips to help you identify and remedy some of the most frequent faults.
Problems
Air jet system
not working
Massage jet system
not working
Heater
not working
Filter system
not working
Filter pump
running too loud
Problem with the filter/air
and massage jets/heater
unit
The tub has a strange
shape
The SPA is losing air
pressure
The SPA is losing water
The water is not clean
Cause
Overheating of the air fan motor
Problem with the filter/air and massage jets/heater
unit
Overheating of the massage jet motor.
Problem with the filter/air and massage jets/heater
unit
Temperature set too low
The water temperature is still within the tolerance
range of the temperature sensor (+/- 2°C)
The filter cartridge is dirty
Water level too low
Problem with the filter/air and massage jets/heater
unit
The filter cartridge is dirty
Water level too low
Problem with the filter/air and massage jets/heater
unit
The filter cartridge is dirty
Water level too low
Dirty cover (on filter cartridge)
Power voltage too low or incorrect frequency
Fault in the filter/air and massage jets/heater unit
Additional air pressure due to strong sunlight
Air valve cap is too loose
Tear (seam) or spot damage
The sealing plug of the water drain at the bottom of the
SPA is loose
Insufficient filtering time
The filter cartridge is dirty
Poor or insufficient water treatment
Solution
Wait until the motor has cooled down, then press the
BUBBLE button to activate the function.
Disconnect the power supply, wait 10 minutes before switching the
power back on.
Wait until the motor has cooled down, then press the
JET button to activate the function.
Disconnect the power supply, wait 10 minutes before switching the
power back on.
Set a higher temperature (20-40°C)
The heating system does not switch on immediately, but after a delay.
Replace the filter cartridge
Top up the water
Disconnect the power supply, wait 10 minutes before switching the
power back on.
Replace the filter cartridge
Top up the water
Disconnect the power supply, wait 10 minutes before switching the
power back on.
Replace the filter cartridge
Top up the water
Clean the cover
Contact a qualified electrician
Disconnect the power supply, wait 10 minutes before switching the
power back on.
Check the air pressure and let some air out, if necessary. This is important in
order to prevent damages
Tighten the air valve cap
Perform a test to locate the affected area.
Clean the sealing plug and press it hand-tight into the drain opening
Increase the filtering time
Replace the filter cartridge
Read the instructions of the chemicals manufacturer

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis