Code
Name
P00
Mandatory defrosting
P03
Water pump
P07
Water temp. calibration
P08
Adjustable for P9-P11
P09
Compressor Frequency
P10
Opening degree of EEV
P11
Fan motor rotate speed
P14
Restore to factory settings
P16
Product code
P17
WIFI or Modbus
P18
Mode
Remark: Logic of filtration pump control
Option 1; P3=0 Filtration pump is related to heat pump operation to start and stop.
Filtration pump starts 60s before compressor, filtration pump start 30s and then the water flow switch detect
flow. Before the heat pump enters into Standby mode, the compressor stops first and after 5 minutes filtration
pump stops.
Mode
Condition
P3=0,
Heating
T1≥Tset-0.5℃,
mode
last for 30
minutes
P3=0,
Cooling
T1≤Tset+0.5℃
mode
, last for 30
minutes
Option 2; P3=1 Filtration pump is always on, P2=0 the timer function is no active
Under condition P3=1, whenT1≥Tset+1℃(T1≥29℃) last for 3 minutes, heat pump will be in standby, while
filtration pump is always on.
Condition for the heat pump start, timer ON actives;
When the timer reaches the set time of TIMER ON, the filtration pump will start and after 5 minutes the
heat pump start. The heat pump stays in stop if the water in temperature is ≥ Tset+1℃, before the TIMER
Scope
0-1
0-1
-9~9
0~1
18~110
0~470
300~100
0~1
/
0-1
0~1
Example
1. Then it enters into
P3=0,
standby mode for 1 hour
T1≥27.5℃,
(It will not restart except
last for 30
turn it on manually.)
minutes
P3=0,
1. Then it enters into
T1≤28.5℃,
standby mode for 1 hour
last for 30
(It will not restart except
minutes
turn it on manually.)
Default
0: Default normal operation
0
1: Mandatory defrosting.
1:Always running;
0
0:Depends on the running of compressor
0
Default setting: 0
1: Adjustable for P9, P10, P11
0
0: Not adjustable for P9, P10, P11
50
Adjustable if P08=1
350
Adjustable if P08=1
500
Adjustable if P08=1
1: Restore to factory settings
0
0: Default (restore P00, P03, P07, P08, P09, P10,
P11 to factory setting)
/
Depend on the machine
0: Modbus
1
1: WIFI
1: Heating only
0
0: Heating/Cooling/Auto mode
Water pump working logic
- 15 -
Remark
2. After 1 hour, the filtration pump
will restart for 5 minutes. If the
T1≤27℃, the heat pump will start
to work until T1≥27.5℃ and last
for 30 minutes to go into standby
2. After 1 hour, the filtration pump
will restart for 5 minutes. If it tests
T1≥29℃, the heat pump will start
to work until T1≤28.5℃ and last
for 30 minutes to go into standby