4.3
Accessories Installation
Anti-vibration bases
1. Take out 4 Anti-vibration bases
2. Install them on the bottom of
machine.
Draining plug
1. Install the draining plug under
the bottom panel
2. Connect with a water pipe to
drain out the water.
Note: Lift the heat pump to install
the draining plug. Never overturn
the heat pump, it could damage the
compressor.
Water Inlet & outlet connection
1. Install the two joints like the
picture shows
2. Screw them onto the water Inlet
& outlet connection
Mains Cable wiring
1. Open the top cover of the heat
pump.
2. Connect the cables in the correct
terminal according to electric
diagram.
Filtration pump wiring (Dry
contact)
1. Open the top cover of the heat
pump.
2. Connect the cables in the correct
terminal according to electric
diagram.