Herunterladen Inhalt Inhalt Diese Seite drucken

Bering INVERBOOST PX Benutzer- Und Wartungshandbuch Seite 18

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Code
d00
IPM mould temperature
d01
Inlet water temp.
d02
Outlet water temp.
d03
Ambient temp.
d04
Frequency limitation code
d05
Piping temp.
d06
Gas exhaust temperature
d07
Step of EEV
d08
Compressor running frequency
d09
Compressor current
d10
Current fan speed
d11
Error code for last time
Remark:
d4: Frequency limitation code,
1: Coil pipe temperature limit;
4: Drive Current frequency limit;
16: Drive high temperature frequency limit
7.2.7
Parameter setting
Select
and press
to set.
Note: Press
and hold 15s in order to set the values
Condition
0: No frequency limit;
2: Overheating or overcooling frequency limit;
8: Drive voltage frequency limit;
to enter, press
Scope
0-120℃
-9℃~99℃
-9℃~99℃
-30℃~70℃
0,1,2,4,8,16
-30℃~70℃
0℃~C5℃ (125℃)
0~99
0~99Hz
0~30A
0-1200 (rpm)
All error code
and
to choose P00-P18 value and press
of P14, P17 and P18
- 14 -
Remark
Real testing value
Real testing value
Real testing value
flash if Real value<-9
Real testing value
flash if Real value<-9
Real testing value
N*5
Real testing value
Real testing value
Real testing value
.