FEATURES

• Professional 4-channel DSP-based class D power amplifier
• 4 x 240W (IPA 424 T) or 4 x 120W (IPA 412 T) @ 4 Ohm / 100V / 70V
• 4 balanced line inputs and 4 speaker outputs with terminal block connections
• User-friendly front panel design with signal, limit, protection, mute and bridge mode LEDs per channel
• Clip LEDs for the inputs and level controls for the outputs on the back
• On/off switchable auto standby mode
• Stereo/parallel/bridge mode selector per channel pair
• Toroidal output transformer per channel
• Low-impedance outputs, completely separated from the output transformers, for optimal audio quality in Low-Z applications
• DSP presets with HP and LP filter which can be activated via DIP switch
• Speaker protection circuits: DSP limiter, overcurrent, direct current, overheating, short circuit
• The REMOTE audio and control bus is based on CAN architecture (Controller Area Network) and enables interaction with future remote control
panels and paging microphones
• Slot for future optional expansion cards:
- An Ethernet expansion card providing access to all internal DSP settings and the analog input gain and increases the input dynamic range by up to 10 dB
- An Ethernet + Dante expansion card with the same functionality as the Ethernet expansion card plus Dante connectivity
• Fault relays with terminal block connections per channel pair
• Universal wide-range PFC switching power supply
• Temperature-controlled active cooling with low-noise fans in 2 zones

PACKAGING CONTENT

• 1 x LD Systems IPA 424 T or IPA 412 T installation amplifier with pre-assembled rack brackets
• 2 x 6-pole terminal blocks for the audio inputs (pitch 3.81 mm)
• 4 x 4-pole terminal blocks for the speaker outputs (pitch 5.08 mm)
• 2 x 3-pole terminal blocks for the fault relay connections (pitch 3.81 mm)
• 1 x RJ45 REMOTE bus terminating resistor
• 1 x IEC power cable
• 1 x user manual

CONNECTIONS, CONTROLS AND DISPLAY ELEMENTS

Note: The connections, controls and display elements for both models IPA 424 T and IPA 412 T are identical.
1
2
3
EXPANSION SLOT
POWER CONNECTOR
1
IEC power connector for the device's power supply. A suitable power cable is provided.
FUSE
2
Fuse holder for 250 V miniature fuses (5 × 20 mm). CAUTION: Only replace the fuse with a fuse of the same type (T10AL/100-120V; T5AL/220-240V).
See information on the housing. If the fuse blows repeatedly, please contact an authorised service centre.
ON / OFF
3
Rocker switch to turn the device on and off.
ON
DIP
ON
DIP
1
2
3
4
1
2
3
4
16
OUTPUT SECTION
ON
ON
DIP
DIP
1
2
2
3 4
3 4
ON
DIP
ON
DIP
1
2
3
4
1
2
3
4
ON
ON
DIP
DIP
1 2
2
3 4
3 4
INPUT SECTION
5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ipa 424 tLdipa412tLdipa424t

Inhaltsverzeichnis