12. Naked flames must not be used as a light source for inspecting and checking equipment.
13. Never use caustic solvents, which may damage materials of the pneumatic system.
14. After performing installation or other work, ensure that no instruments, rags or spare
parts have been left inside the equipment.
15. Pay particular attention to the safety-relief valves. Thoroughly inspect them and remove
any dust and dirt. They must not be allowed to suffer any loss in function under any circum-
stances. Remember that your safety depends on their functionality!
16. Before beginning work in normal mode after maintenance or repair work, check that the
working pressure, temperature and other characteristics are correctly set. Ensure that all
control devices are installed and functioning properly.
17. When replacing filters, separators etc., wipe away dust, dirt and oil residue from the
area where they are installed with a dry cloth.
18. Protect the motor, air filter, electrical components and control components etc. from
coming into contact with condensate. For instance, blow down with dry air.
19. Use protective gloves during installation and repair work in order to avoid burns and
injury (for instance, during oil change).
2.

Technical data and functional description

2.1

Technical data

Article
Model
11100061 A3008
11100062 A3010
11100063 A3013
11100071 A3708
11100072
A3710
11100073 A3713
11100081 A4508
11100082 A4510
11100083 A4513
11100091 A5508
11100092 A5510
11100093 A5513
8
Entitlement to free handling of faults arising during the guarantee pe-
riod is forfeited when:
- No warranty service coupon for the compressor or it is filled out
incorrectly
- No records for the compressor's scheduled maintenance are entered
in the compressor's service book
- Unoriginal parts and lubricants are used
Drive power,
Max. operat-
compressor
ing pressure
(kW)
(bar)
8
30
10
13
8
37
10
13
8
45
10
13
8
55
10
13
Rated
Output
voltage,
(m 3 /min)
compressor
(phase/V/Hz)
4,7
4,0
3,5
5,9
5,1
4,4
3/380/50
7,0
6,2
5,3
8,7
7,7
6,5
Noise
Screw
(dB)
connection
70
1-1/4
72
1-1/2
73
Version 4.5
Oil
capacity,
liter
15
20