3.3 Requirements on installation facility
Fig. 3.3 Installation facility proposal A30 – A55.
1. Air inflow
2. Air outflow
Ensure that the floor of the facility can withstand the weight of the compressor. Install the
compressor on a level surface that is able to bear its weight.
Adjust the horizontal axis of the compressor using a levelling instrument.
If the compressor is not anchored to the base on which it is installed, the tilt angle with
respect to the horizontal surface must not exceed 3°.
If the compressor is anchored to the base on which it is installed, the tilt angle with respect
to the horizontal surface must not exceed 7°.
Install the compressor in a facility where precipitation cannot reach.
14
Compressor dimensions
Length
Width
L, mm
D, mm
1400
1000
1650
1100
1500
Height
Weight,
H,mm
kg
705
1500
745
950
1730
1150
1500
1
1500
Packaging dimensions
Length
Width
L, mm
D, mm
1600
1100
1850
1200
2
Height
Weight,
H,mm
kg
777
1750
830
1165
1860
1194
Version 4.5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis