INSTALLING AN AIR KIT ON THE REAR SIDE
Remove the cover on the rear side of the fireplace insert and
detach the cover plate (6) using a 3 mm Allen key (5).
Re-fit the cover plate to the underside of the fireplace insert
using the four M5 screws (4) ensuring that the air box is sealed.
Fit the spigot (1) on the rear of the fireplace insert and secure
the flexible hose (3) using the hose clamp (2).
1
5
2
3
1. Spigot
2. Hose clamp
3. Flexible hose
4. M5 screw
5. Allen key - 3 mm
6. Cover plate
20 - GB
EXTERNAL AIR CONNECTION - AIRSYSTEM
Cover
ITEM
PART NUMBER
1
1710912sv
2
0710-SLANGEBÅND
3
0710-FLEKSSLANGE
4
0110-M5x6 CYL RÅ LH
5
0110-UNBR.NØGLE 3MM
6
11-0000-040110
6
4
TITLE
Air connexion
Slangebånd ABA Ø87/112
0110-M5x6 CYL RÅ LH
Cover
1
5
2
3