Force Mode. [Press & Hold for 5 seconds]
Force mode allows the charger to manually begin charging when the connected battery's voltage is too low to be detected. If battery voltage is too low for
the charger to detect, press and hold the mode button for 5 seconds to activate Force Mode, then select the appropriate mode. All available modes will
flash. Once a charge mode is selected, the Charge LEDs and the selected mode LED will alternate between each other, indicating Force Mode is active.
After five (5) minutes the charger will return to the normal charge operation and low voltage detection will be reactivated.
CAUTION. USE THIS MODE WITH EXTREME CARE. FORCE MODE DISABLES SAFETY FEATURES AND LIVE POWER IS PRESENT AT THE CONNECTORS.
ENSURE ALL CONNECTIONS ARE MADE PRIOR TO ENTERING FORCE MODE, AND DO NOT TOUCH CONNECTIONS TOGETHER. RISK OF SPARKS, FIRE,
EXPLOSION, PROPERTY DAMAGE, INJURY, AND DEATH.
Using "Reduced Charge Current Mode". [Press the 10A Mode Button]
Reduced Charge Current mode will allow the unit to operate at a charge current of 10A. This mode is available at any time and can be used with the
following modes only: 12V AGM, 12V LITHIUM, 6V, 6V AGM, 6V LITHIUM, 24V, 24V AGM, 24V LITHIUM and Force mode.
Connecting to the Battery.
Do not connect the AC power plug until all other connections are made. Identify the correct polarity of the battery terminals on the battery. Do not make any
connections to the carburetor, fuel lines, or thin, sheet metal parts. The below instructions are for a negative ground system (most common). If your vehicle
is a positive ground system (very uncommon), follow the below instructions in reverse order.
1.) Connect the positive (red) eyelet terminal connector to the positive (POS,P,+) battery terminal.
2.) Connect the negative (black) eyelet terminal connector to the negative (NEG,N,-) battery terminal.
3.) Connect the battery charger into a suitable electrical outlet. Do not face the battery when making this connection.
4.) When disconnecting, disconnect in the reverse sequence, removing the negative first (or positive first for positive ground systems).
Begin Charging.
1.) Verify the voltage and chemistry of the battery.
2.) Confirm that you have connected the battery clamps or eyelet terminal connectors properly and the AC power plug is plugged into an electrical outlet.
3.) [First time use] The charger will begin in Standby mode, indicated by an orange LED. In Standby, the charger is not providing any power.
4.) Press the mode button to toggle to the appropriate charge mode (press and hold for three seconds to enter an advanced charge mode) for the voltage