For charging 24-volt AGM batteries, which requires a higher than normal charging voltage. When selected, the 24V AGM white LED will illuminate.
Press & Hold
(3 Seconds)
29.6V | 25A | Up To 1000 AH Batteries
For charging 24-volt lithium iron phosphate (LiFePO4). When selected, the 24V Lithium blue LED will illuminate. For use on batteries with Battery Management
Systems (BMS) only.
Press & Hold
(3 Seconds)
29.2V | 25A | Up To 1000 AH Batteries
For charging batteries with a voltage lower than 1V. Press and Hold for five (5) seconds to enter Force Mode. The selected charge mode will then operate under
Force Mode
Force Mode for five (5) minutes before returning to standard charging in the selected mode. This mode is available at any time and can be used with the following
modes only: 12V, 12V AGM, 12V LITHIUM, 6V, 6V AGM, 6V LITHIUM, 24V, 24V AGM, and 24V LITHIUM.
Press & Hold
(5 Seconds)
50A (6V, 12V) | 25A (24V)
Converts to a DC power supply for powering any 12VDC device, like a tire inflator, oil changer, or as a memory retainer when replacing a battery. When selected,
a red LED will illuminate.
13.6V | Max 50A
Converts to a DC power supply for powering any 24V DC device, like a tire inflator, oil changer, or as a memory retainer when replacing a battery. When selected,
a red LED will illuminate.
Press & Hold
(3 Seconds)
27.2V | Max 25A
An advanced battery recovery mode for repairing and restoring, old, idle, damaged, stratified or sulfated batteries. When selected, a red LED will illuminate and
flash.
Press & Hold
(3 Seconds)
Up To 8V | 3A | Up To 2000 AH Batteries
An advanced battery recovery mode for repairing and restoring, old, idle, damaged, stratified or sulfated batteries. When selected, a red LED will illuminate and
flash.
Press & Hold
(3 Seconds)
Up To 16V | 3A | Up To 2000 AH Batteries
An advanced battery recovery mode for repairing and restoring, old, idle, damaged, stratified or sulfated batteries. When selected, a red LED will illuminate and
flash.
Press & Hold
(3 Seconds)
Up To 32V | 1.5A | Up To 1000 AH Batteries
10A MODE
Reduced Charge Current mode will allow the unit to opperate at a lower charge current. This mode is available at any time and can be used with the following
modes only: 12V, 12V AGM, 12V LITHIUM, 6V, 6V AGM, 6V LITHIUM, 24V, 24V AGM, and 24V LITHIUM.
Press the 10A
Mode Button
10A | Up to 400 AH Batteries
[From Standby Press and Hold 5 Seconds while connected to battery, then toggle through modes]
[Press and Hold 3 Seconds while NOT connected to battery]
[Press and Hold 3 Seconds while NOT connected to battery]
[From Standby Press and Hold 3 Seconds while connected to battery]
[From Standby Press and Hold 3 Seconds while connected to battery]
[From Standby Press and Hold 3 Seconds while connected to battery]
[From Standby Press the 10A Mode Button while connected to battery]