3.4. Sensor operating modes

The sauna control unit can be operated with one or two temperature sensors.
Single-sensor mode (F1)
Single-sensor mode must be activated in the technician menu (see 8.2. Settings
in the technician menu on page 26).
In single-sensor mode, the sauna control unit is operated with the heater sensor
with excess temperature fuse (F1) only.
In single-sensor mode, the sauna control unit only displays the set temperature
as standard. The actual temperature is not displayed. Should the sauna control
unit display the temperature above the heater (F1) as an actual temperature in
single-sensor mode, it must be activated when starting up for the first time (see
8.2. Settings in the technician menu on page 26)
Two-sensor mode with bench sensor (F2)
In two-sensor mode with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna control unit displays
the temperature measured by the bench sensor as the actual temperature.