1 | General information
2

Safety

Before using the product for the first time, please read through the safety instructions carefully.
DANGER
Lethal voltages are still present in the connections and cables of the device even after the device
has been switched off and disconnected!
Severe injuries or death may occur if the cables and/or terminals/busbars in the device are touched.
1. The device must be mounted in a fixed position before being connected electrically.
2. Comply with all safety regulations and current technical connection specifications of the responsible power
supply company.
3. The device is only permitted to be opened or serviced by a qualified electrician.
4. Switch off the grid voltage by turning off the external circuit breakers.
5. Check that all AC and DC cables are completely free of current using a clip-on ammeter.
6. Do not touch the cables and/or terminals/busbars when switching the device on and off.
7. Keep the device closed when in operation.
The electrician is responsible for observing all existing standards and regulations. The following applies:
– Keep unauthorised persons away from the device and/or system.
– In particular, making sure that the locally applicable version of the standard
or locations – solar photovoltaic (PV) power supply systems" is observed.
– Ensure operational safety by providing proper grounding, conductor dimensioning and appropriate protection against
short circuiting.
– Observe all safety instructions on the product and in these operating instructions.
– Switch off all voltage sources and secure them against being inadvertently switched back on before performing visual
inspections and maintenance.
– When taking measurements on the live device:
– Do not touch the electrical connections
– Remove all jewellery from wrists and fingers
– Ensure that the testing equipment is in safe operating condition.
– Modifications to the surroundings of the device must comply with the applicable national and local standards.
2.1

Proper use

The device is a transformerless PV inverter which converts the direct current of the PV generator into grid-com-
patible three-phase alternating current and then feeds the three-phase alternating current into the public
power grid.
The device is built using state-of-the-art technology and in accordance with the recognized safety rules. Never-
theless, improper use may cause lethal hazards for the operator or third parties, or may result in damage to the
product and other property.
The device is intended for indoor and outdoor applications and may only be used in countries for which it has
been approved or for which it has been released by KACO new energy and the grid operator.
1
Country
EU
USA
Tab. 1: Examples of standards specific to business premises
2
Page 6
Operating Instruction I
Standard
Harmonised document - HD 60364-7-712 (European im-
plementation of the IEC standard)
PV section of NEC 690 and sections in article 100, 690.4,
690.6 and 705.10
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 105 TL3 KACO blueplanet 110 TL3
KACO blueplanet 125 TL3 KACO blueplanet 137 TL3 KACO blueplanet 150 TL3 KACO blueplanet 155 TL3
1
"Requirements for special installations
2
KACO blueplanet 165 TL3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis