Technical data

11.1 Electrical data

DC Input levels
Recommended generator
power range
MPPrange@Pnom
Working range
Rated voltage
Starting voltage
61
Open circuit voltage
62
Max. input current
Number of strings
Number of MPP controls
Max. short-circuit current (ISC
max.)
Input source feedback current
Polarity safeguard
String fuse
DC overvoltage protection
Recommended generator
power range
MPPrange@Pnom
Working range
Rated voltage
Starting voltage
61
Open circuit voltage
62
Max. input current
Number of strings
Number of MPP controls
61
A brief open circuit voltage of up to 1600 V
Due to the brief open circuit voltage exceedance, there is no guarantee that the integrated overvoltage protection
will work correctly if the ambient temperature is > 40°C.
62
The "Max. input current" is the maximal theoretical value during operation at full power and minimal MPP voltage.
The inverter will clip to the maximum AC power output.
The "Max. short-circuit current (ISCmax.)" defines together with open circuit voltage (Uocmax) the characteristic of
the connected PV generator. This is the relevant value for string sizing and is the absolute maximal limit for inverter
protection. The connected PV-Generator must be designed, that the max short circuit current is below or equal to
ISCmax of the inverter under all foreseeable conditions. In no condition the design may result in a greater short cir-
cuit current than ISCmax of the inverter.Designing the PV generator [See section 6.6.2}[19].
278
KACO blue-
KACO blue-
planet
planet
87.0TL3
92.0TL3
130.5 kW
138 kW
563 V - 1300
591 V-1,300 V 705 V-1,300 V 875 V-1,300 V
V
563 V - 1450
591 V-1,450 V 705 V-1,450 V
V
600 V
620 V
645 V
675 V
KACO blueplanet
KACO blueplanet 125
105TL3
TL3 US
157.5 kW
591-1,300 V
591 V-1,450 V
620 V
673 V
(max. 15 hours a year) is admissible for the device.
dc
KACO blue-
KACO blue-
planet
planet
110TL3
125TL3
Input levels (DC)
165 kW
187.5 kW
875 V -1,450
730 V
805 V
1,500 V
160 A
1-2
1
300 A
0 A
no
no
Yes
KACO blueplanet
155TL3
187.5 kW
705-1,300 V
875 V-1,300 V
705 V-1,450 V
875 V-1,450 V
730 V
804 V
1,500 V
183 A
1-2
1
Operating Instruction I
KACO blue-
KACO blue-
planet
planet
137TL3
150TL3
205.5 kW
875 V -1,300
960 V-1,300 V
V
875 V -1450 V 960 V-1,450 V
V
900 V
1,000 V
KACO blueplanet
165TL3
232.5 kW
247.5 kW
960-1,300 V
960 V-1,450 V
900 V
1,000 V
1,000 V
1,098 V
Kurzanleitung_blueplanet 87.0-165TL3
225 kW
1,000 V
1,100 V
300A