Herunterladen Inhalt Inhalt Diese Seite drucken

Recommended Twisted Pair Cables - G&D DVICenter DP16 Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Recommended twisted pair cables

Recommended twisted pair cables
The transmission of all signals of the DVICenter system is carried out through one
twisted pair cable (category 5e or better).
NOTE:
It is permitted to connect several segments of a cable connection with patch
panels and connection ports. It is, however, not permitted to connect active com-
ponents such as network switches, hubs or repeaters are not permitted.
The data transmission is reliable over a distance of at least 80 metres using a regular
standard twisted pair cable (category 5e or better).
The distance that can actually be bridged depends on the quality of the applied
cable. High-quality S-STP cables with an AWG22 wire gauge coding can bridge a
distance of up to 140 metres.
Patch cables with an AWG26 wire gauge coding can only bridge a maximum of 80
metres.
In order to ensure a reliable operation even in environments with interferences,
installation cables with at least AWG24 coding have to be used for lengths over 80
metres:
Wire gauge
AWG22
AWG24
AWG26/27
NOTE:
The lengths that are mentioned in the table above must be interpreted as the
sum of all segments between the devices.
The following cables achieved the best results during test operation:
up to 80 meters:
up to 100 meters:
up to 140 meters:
9 · G&D DVICenter DP16
Cable type
Installation
Installation
Patch cable
Dätwyler uninet® 7702 flex
Patch cable
Dätwyler uninet® 5502 AWG24 S-STP
Installationcable with sockets
Kerpen MegaLine® G12-150 S/F AWG22
Installation cable with sockets
Dätwyler uninet® 7702 AWG 22
Installation cables with sockets
Category
5e, 6 or 7
5e, 6 or 7
5e, 6 or 7
Recommendation
upto140 m
up120 mr
up 80 m

Werbung