3. Specifications
3.15 Electrical connections model O-10 (5)
Available connections
Electrical connection
EN
Circular connector M12 x 1 (4-pin)
Metri-Pack series 150
Cable outlet, unshielded
1) up to a maximum of 80 °C permitted
The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the
appropriate ingress protection.
Mating connectors are not included in the delivery, but they are available as accessories.
Short-circuit resistance
S + vs. 0V
Reverse polarity protection
U B vs. 0V
Overvoltage protection
DC 36 V
Insulation voltage
DC 750 V
For special model numbers, e.g. O-10000, please note the specifications stated on the delivery note.
For further specifications see WIKA data sheet PE 81.65 and the order documentation.
20
All manuals and user guides at all-guides.com
Ingress pro-
tection
IP65
IP67
1)
IP67
Wire cross-
Cable dia-
section
meter
-
-
-
-
2
0.14 mm
3.4 mm
WIKA operating instructions pressure sensor, model O-10
Cable lengths
-
-
2 m, 5 m