Herunterladen Inhalt Inhalt Diese Seite drucken

Auerswald COMfortel WS-500S Betriebsanleitung Seite 34

Dect-basisstation
Vorschau ausblenden Andere Handbücher für COMfortel WS-500S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Initial Commissioning
You need to know the PBX's IP address
You need to know the mobile device's IPUI
Note: You will find more information in the Instructions/help for the PBX.
Note: You can find out the handset's IPUI on the packaging label or scan
it in. Alternatively, you can view the IPUI on the display. To do so, press
the centre of the control key
The first entry you see is the IPUI. Example: 1: 029E74A560
Carry out these steps:
A PBX profile must be configured for the PBX.
– Perform configuration on the Settings > Provider or PBX profiles page
in the Web configurator on the COMfortel WS-500S/WS-500M
– Necessary settings:
Connection name or number
System
Domain
For each physical mobile device, you must configure a mobile device and
assign that mobile device to the PBX profile.
– Perform configuration on the Settings > Mobile devices >
Administration page in the Web configurator on the COMfortel WS-
500S/WS-500M
– Necessary settings:
IPUI
Authentication name
Authentication
password
Username
Display name
VoIP provider
Each mobile device must be registered on the Integrator/DECT Manager.
34
to display the menu, In it, enter *#06#.
The mobile device's IPUI
The internal telephone number for the mobile
device configured on the PBX
Password for the internal telephone number
The internal telephone number for the mobile
device configured on the PBX
Name (text of your choice) that is to be
displayed on the mobile device
Previously assigned name of the PBX profile
COMfortel WS-500S/500M - Instructions V02 08/2019
Name (text of your choice)
for the PBX profile
Automatic
The PBX's IP address

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Comfortel ws-500m

Inhaltsverzeichnis