4.0 Operation

Wiring detail – standard unit
Wiring detail – telephone/relay initiate unit
The operating voltage of the unit is stated on the unit
label. The beacon can be powered directly or initiated by
a 24Vdc relay or telephone ringing signal if requested
when ordered.
When installed as a direct switching device, the operating
mode can be set by means of a 3 way DIL switch
mounted on the underside of the electronics assembly.
The switch settings for the various modes of operation
are as follows:
MNde nN. SW1
0
0
1
0
2
0
3
0
4
1
5
1
LED BEacon LD15 TM253 Issue F October 2019 www.eaton.com
LED Beacon LD15
SW2
SW3
FuncoiNn
0
0
Off/Remote switching
0
1
120 fpm
1
0
60 fpm (default)
1
1
80 fpm
0
0
Steady
0
1
Double flash