4.

Installation

Observe the respective national regulations as well as the
general rules of engineering which apply to the installation and
operation of electrical apparatus!
Transport and storage of the luminaire is permitted in original
packing and specified position only!
4.1

Opening and closing the light fitting

- Turn the central locking device with a box spanner (opening of the
spanner SW 13) through 90° to its lock-in position and fold down the
protective bowl, see fig. 3+4.
If unsuitable tools are used, a strong tightening of the central
locking system is not guaranteed and it will be damaged.
- Fit in and remove the protective bowl acc. to fig. 6 and 7 .
- The protective bowl can, at option, be hinged on either side.
- To close the light fitting, press the protective bowl tightly onto the
luminaire housing and turn the central locking device through 90°.
4.2

Mounting

See fig. 1 - 11
The integrity of the fitting may be compromised if the fixing
centres are not correctly aligned, see fig. 10­11. When fixing the
mounting accessories onto the light fitting, observe the max. depth
of thread of 14 mm!
Do not use too long screws (Test torque max. 5.0 Nm)!
Installing the light output upwards additional protection has to be
assembled to avoid permanent water accumulations at the protec­
tive bowl gasket area.
Mind:
For handrail mounting (e.g. mounted at 45°) we recommend replacing the
existing cover of the locking bolt with the version part no 22216904000.
In such a case the cover should be fixed with its hinges on the top part of
the housing.
Due to the high ingress protection condensation cannot be avoided
completely. Therefor we recommend the use of a breather plug in outdoor
areas with high humidity and high ambient temperatures.
(e.g. M20 order no. GHG9601954R0014 or
M25 order no. GHG9601954R0002)
Mounting dimensions:
See fig. 2
When fixing the mounting accessories onto the light fitting, observe the
max. depth of thread of 14 mm! Do not use too long screws!
Accessories for mounting:
See CCH/CEAG catalogue.
4.3

Mains connection LLK 98...:

To open the connection box, turn the green handle to its stop in the
direction of arrow, then pull it and fold down the flap, see fig. 3+4.
- Introduce the cable through the cable entry, see fig. 5.
- Use
sealing inserts 1,2 and 3 for cables from 8 to 10 mm Ø,
sealing inserts 1 and 2 for cables from 10 to 13 mm Ø and
sealing insert 1 for cables from 13.5 to 17 .5 mm Ø.
Industrial luminaire Series:
- Plug the bared conductors to the terminals in accordance with the
terminal marking (see wiring diagram).
stripping length 2.5 mm²: 8 - 9 mm
- When using multi- or fine-wire connection cables, the wire ends must
be provided with wire end sleeves or cable lugs.
When screw-terminals are used also tighten vacant terminals! With single
connection of the terminal no bending (loop) of the conductor required!
In case of unused cable entries, remove their protective cover
and close the entries with a blanking plug (test­torque of 3.5 Nm).
When closing the gland with a blanking plug, always use sealing
inserts 1+2!
4.4

Fitting the lamps

Only use bi­pin LED as specified in Technical data and type label!
The bi-pin lamp (G13) is to be inserted to its stop into both holders so that
both pins on either side of the lamp engage in the holder. Then turn the
lamp to its lock-in position, see fig. 8.
5.

Taking into operation

- Prior to operation, check the light fitting for its proper functioning and
installation in compliance with these operating instructions and other
applicable regulations!
- Only carry out insulation measurements between PE and the external
conductor L1(L,L2,L3) as well as between PE and N!
- measuring voltage: max. 1 kV AC/DC
- measuring current: max. 10 mA
- The light fitting may only be operated closed.
6.

Maintenance

Observe the national regulations applicable to the maintenance,
servicing and test of electrical apparatus as well as the general rules
of engineering!
6.1

Servicing

When servicing, in particular those components that affect the type of
protection, will have to be checked, e. g.:
- Housing and protective bowl for any cracks or damages.
- Gaskets for their perfect condition.
- Terminals and blanking plugs for their firm fit.
- Because of the risk of an electrostatic charge, the light fitting shall only
be cleaned with a damp cloth or sponge!
Only use customary household washing-up liquid diluted in water as
specified! The water temperature may be max. 50ºC. After that, rinse
with clear water to prevent the risk of tension cracks in the protective
bowl!
- Lamp replacement: Keep replacement intervals as specified by the lamp
manufacturer!
6.2

Repair

Prior to replacing or removing any components, observe the
following:
Cut the apparatus off the voltage before opening it or carrying out
repairs!
Only use certified genuine CCH/CEAG spare parts! (See CCH/CEAG spare
parts list).
Subject to alteration or supplement of this product series.
Regarding waste disposal, observe the relevant national regulations!
All components are marked with relevant material signs.
LLK 98 LED