PERMANENT WATER DRAIN
You have the option to install a permanent water drain, so you
do not have to drain the water tank manually each time you
intend the use the unit for a longer period (or if the water pump
fails).
The air conditioner has two separate condensation water outlets
for different modes
 DRY MODE  Middle water drain
 COOL MODE  Lower water drain
Please use the correct water outlet for permanent installation,
because the outlets are tuned to each mode.
To install the permanent water drain, please proceed as follows:
Before you attach a suitable water drainage hose
(12.7mm) to the respective outlet, the water tank must
be completely emptied.
Remove the plug of the permanent condensation water
outlet and attach the drain hose.
Place the other end of the hose in a receptacle or drain,
with the hose not higher than the drain valve and not
kinked.
If the permanent drain is removed, be sure to reinsert the
plug carefully.
NOTE:
You can also attach both hoses at once if you do not want to change them while changing
modes.