To exit the advanced settings, press

13.5 Resetting factory settings

If PIN code protection is disabled, user and installation settings are reinitia-
lized:
1- From the internal temperature monitoring setting, press
splay briefl y shows
.
2-
is displayed. Press
= Reset to factory settings..
= Cancel reset to factory settings

14.Power supply failure

14.1 Reserve charge in case of power failure

• When power failure is lower than 3h, the device restarts itself, there is
nothing to set. All setting parameters, including time, have been saved.
When power is restored, the device will reactivate all settings perfor-
med before the failure (set temperature, operating mode, programs,
time, etc.). It restarts in the same mode as before the failure.
• When power failure exceeds 3h, check the time update. All the other
settings have been saved automatically and permanently.
15.Maintaining and cleaning the dust fi lter
Before any maintenance work, switch off the device by pressing the pro-
per switch.
The device can be cleaned with a damp cloth; never use abrasives or
solvents.
Cod. 1910000002086 - nv00
3 times.
or
to select
.
3- Press key
ration and automatically switches to Auto mode.
The following factory settings are reset:
Settings
. The di-
Set Comfort temperature
Set Eco temperature
Boost time
Keyboard lock
Backlighting
Frost protection temperature
Maximum Boost time
Maximum ambient temperature for
automatic Boost shutdown
Automatic open window detection
Presence detection
PIN code protection
PIN code numbers
Sensor adjustment
Hysteresis adjustment
Internal temperature monitoring
To exit the advanced settings, press
• Maintaining and cleaning the dust fi lter
The fan is equipped with a removable dust fi lter that retains impurities
from the air drawn into the room. When the fi lter is full, the accumulation
of dust can cause a stop. To clean the fi lter, proceed as follows:
In Boost mode,
- 39 -
for 5 seconds. The device returns to its initial confi gu-
Factory settings
Operation
19°C
15°C
60 min.
Disabled
User settings
L3
7°C
60 min.
25°C
Installation settings
Enabled
Enabled
Disabled
0000
Advanced settings
0.0
1.0°C
65°C
3 times.
is displayed.
English