Herunterladen Inhalt Inhalt Diese Seite drucken

User Information; Installer Information; Positioning In Bathrooms; Wall Mounting - Cordivari CLAUDIA BLOWER MISTO 500X763 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63

4. User information

To clean painted radiators, use only a non-abrasive cloth soaked in
water. To clean stainless steel radiators, use a non-abrasive cloth
soaked in water and 50% diluted methyl alcohol. Never use detergents or
aggressive substances. Avoid any other base or acid solution, chemical,
industrial or other substances, aggressive or corrosive substances
(bleach, ammonia, baking soda...). Do not use abrasive cloths or sponges

5. Installer information

This product is subject to the general warranty conditions set forth in the
current offi cial Cordivari catalogue. The warranty is valid from the date
of delivery and is void if the production batch label is tampered with and/
or removed. The warranty applies after the examination of defects and
their causes. The material to be replaced or repaired shall be delivered
ex-warehouse at the dealer. The commitment to provide the warranty is
subject to the conditions and requirements described below.
The radiator has not been damaged during transport, handling or
installation and no repair and/or tampering has been carried out by third
parties without express authorisation. Before installation, the material has
been stored in good conditions and under shelter form the weather. Product
installation must be carried out by qualifi ed personnel and in compliance
with these instructions and all national and local regulations concerning
installation and safety. Do not place the radiators in rooms with chlorine
vapours or corrosive fumes, e.g. pools, saunas, thermal pools.

6. Positioning in bathrooms

The national regulations on installation of electrical equipment in
bathrooms must be scrupulously observed (in Italy CEI 64-8). Radiators
equipped with a fan heater must always be installed outside Zones 1
and 2. The power socket, the switch and the control elements must be
positioned in zone 3 so that no electric control element is accessible by a
person using the shower or the bath tub.
ZONE 1
ZONE 2
ZONE 3
Position the radiator so that the minimum distance of the thermostat from
the ground is 250 mm and no obstacle is present at a minimum distance
of 100 mm from the equipment.

7. Wall mounting

The radiators must be fastened to the wall according to the assembly
instructions contained in the fastening support package. The fastening
systems (screws + blocks) are suitable for compact walls or hollow brick
walls. For walls made of diff erent materials, the installer is responsible
for the use of suitable fastening systems. The fan heater, in the correct
orientation of the radiator, is located at the bottom, with the air supply
opening facing opposite the wall. The radiator must never be installed
with the fan heater in a diff erent position or direction than shown.
Do not position the radiator in front of the power socket.
Cod. 1910000002086 - nv00
ZONE 0

8. Electrical connection

All Cordivari Mixed Radiators are equipped with connection cable with pre-
assembled Schuko plug. Before connection, make sure that the equipment
rated voltage (230 V) is equal to the mains voltage, and that the wall socket
is able to provide the rated current corresponding to the maximum power
of the model selected. In addition, this socket must be controlled by a
bipolar switch to be used to turn the radiator on and off . In case of damage,
the power cable of these radiators can be replaced. Such repair must be
carried out solely and exclusively by the manufacturer.

9. Warnings

During normal operation, the radiator surfaces are hot. Only fabrics
washed with water may be dried on the radiator.
The towel warmer must be positioned so that the electronic control can
perfectly detect the room temperature, far from external heat sources
Caution!
Never cover the fan heater.

10. Operation

10.1 Diagram

• Buttons on the device
2
1
1.
Selection of the operating mode
2.
Plus and minus buttons, used to set temperature, time, day and
programs
3.
Setting saving
4.
Boost
- 25 -
English
2
3
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis