Maintenance

5.
Maintenance
• Always after 10.000 work cycles the operating pressure has to be controlled
and the hydraulic oil must be changed. In order to avoid damage at the
sensitive hydraulic system we recommend insistently to assign our service
department with this maintenance.
• All movable parts have to be cleaned and greased regularly. Furthermore all
parts have to be checked for damage and abrasion.
• The tool must be stored in a dry area. If the storage temperature has been
below 5 °C for a longer period, the tool must be warmed up to room
temperature at least for one hour before using.
• The tool shouldn't be stored at a temperature of more than 60 °C.
• We recommend a regularly inspection of the tool by our service
department (at least once a year).