Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Care; Maintenance; Mechnical - probst KKV-8/14 Betriebsanleitung

Kabelkanal-versetzzange
Vorschau ausblenden Andere Handbücher für KKV-8/14:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Instructions
KKV 8/14

8 Maintenance and care

8.1

Maintenance

To ensure the correct function, safety and service life of the device the following points must be executed in the
maintenance interval.
Used only original spare parts, otherwise the warranty expires.
All operations may only be made in unpressurised, electro less and closed state of the device!
8.2

MECHNICAL

SERVICE INTERVAL
First inspection after
25 operating hours
All 50 operating hours
Minimum 1x per year
(at rough conditions shorten the
interval)
13 / 15
Maintenance and care
Maintenance work
Control and tighten all screws and connections.
(The implementation is only allowed by an expert).
Tighten all screws and connections (take care that the tightening torques according
to the property class of the screws are observed).
Check all joints, bolts, guidance's and gears for correct function, if necessary adjust or
replace it.
Check all Grippers ( if available) for signs of wear.
Grease all slidings ( if available) when the device is in opened position with a spatula.
Check of all the suspension parts, bolts and straps. Check for corrosion and safety by
an expert.