7. Minimum clearances
The dimensions given are minimum values and may differ from the local building and fire regula-
tions. These must be observed and complied with in any case.
The illustrated installation surfaces must comply at least with fire protection class A2.
Please note: The HEATSCOPE® ZERO fulfills IP protection class 4 (IPX4) for ceiling mounting and IP
protection class 0 (IPX0) for wall mounting.
Vorgeschriebene Abstände zu brennbaren Montageflächen:
A
min. 12 inch/30cm to wall
min. 3 inch/6 cm to another HEATSCOPE® ZERO
B
min. 12 inch/30cm
C
min. 32 inch/80 cm to furniture below the HEATSCOPE® ZERO
D
min. 3 inch/210 cm
E
min. 3 inch/6 cm to combustible surfaces
(MHSDAHS4 madatory)
F
min. 8 inch/20 cm
G
min. 6 inch/12 cm
(MHSWH45, MHSWHSL or MHSDAHGMS madatory)