Error Codes - Heatmiser SmartStat Anleitung

Raumthermostat
Inhaltsverzeichnis

Werbung

Schaltplan – Schalter spannungsführend an UH3/UH8
Re-calibrating the SmartStat
If you need to re-calibrate the SmartStat, follow these steps.
Use the Left / Right keys to scroll to the Power Icon ..................................
Press and hold Tick to turn the display OFF ...................................................................
Press and hold the Tick and Down keys together for 4 seconds ...................
The current temperature will appear on the display.
Use the Up / Down keys to configure the new temperature value ..............
Press the Tick key to confirm the change and the display will go blank .............
Press the Tick key once to turn the thermostat ON .....................................................
Luftfernsonde

Error Codes

Bodensonde
When terminated for thermostat operation the screen will display an error code if a fault
is detected.
E0 = The internal sensor has developed a fault.
E1 = The remote FLOOR probe has not been connected.
The remote FLOOR probe has not been wired correctly.
The remote FLOOR probe is faulty.
E2 = The remote AIR probe has not been connected.
Dieses Produkt darf nur durch einen Elektrofachmann installiert
The remote AIR probe has not been wired correctly.
werden und muss den örtlichen Installationsvorschriften entsprechen.
The remote AIR probe is faulty.
31
TIMER
-
RT2
RT1
N
L
N
UH3/UH8
L
NO
NC
COM
SL