5.2 Wall attachment of product assembly
WARNING!
Danger to life!
Improper installation may lead to
extensive injuries to persons and
damage to property.
For this reason:
– Have installation only carried out
by a qualified gas and water spe-
cialist.
– Have any work at the electrical in-
stallation only carried out by a qua-
lified electrician.
1.
After removal of the packaging material, take
off front insulation shell.
2.
Lift product assembly out of rear insulation
shell.
3.
Fit enclosed angled wall bracket (1) into rear in-
sulation shell (2) (arrow) from behind and click
into position.
4.
Hold rear insulation shell to required installa-
tion place and position.
5.
Adjust perpendicular position of the rear insu-
lation shell with the help of the spirit level.
6.
Mark drill holes for the angled wall bracket on
the wall.
7.
Take rear insulation shell off the wall.
8.
Drill holes for the angled wall bracket and
equip with dowels.
9.
Remove angled wall bracket from the rear
insulation shell and mount onto wall using
screws M8x70 and the enclosed washers.
Illustr. 17: Rear insulation shell, angled wall bracket