Herunterladen Inhalt Inhalt Diese Seite drucken

Pelgrim GKT814 Anleitung Seite 90

Gaskochmulde
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

FAULTS
Symptom
The burner does not burn
evenly.
The burner goes out after
igniting.
Fault code 'b'.
Fault code 'Flt0A', all burners
are locked.
Fault code 'Flt06'.
Fault code 'Flt09'.
Other fault codes.
GB 18
Possible cause
Burner parts fitted incorrectly.
Burner parts dirty or damp.
Wrong type of gas used.
Control knob not kept
depressed for long enough.
The burner is locked.
There is no gas supply.
You have attempted to unlock
a burner up to 5 times within
a period of 15 minutes.
A burner is switched off due
to an unknown fault.
Solution
Assemble the burner parts
using centring bosses.
Clean / dry the burner parts.
Check to see whether the
outflow holes are open.
Check that the gas used is
suitable for the appliance. If
not, contact your gas fitter.
Keep the control knob
depressed for at least
5 seconds.
Unlock the burner, see
page 11.
Restore the gas connection
and unlock the burners.
You are not permitted to
make any further attempts
at unlocking the burner for a
further 15 minutes.
Unlock the burner.
Contact the service
department.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gkt831Gkt832Gkt875Gkt895

Inhaltsverzeichnis