Door strike for AC function

An
AC function
can be realized via a door strike at the latch bolt when the system is in a disarmed
state. A fail secure door strike or a fail safe door strike can be used as a door strike.
Applicable door strikes:
- Strike with load current function
- Strike with no-load current function
The AC function is active when in a "disarmed" state.
PIN codes and/or keys (data carriers) can be authorized for door release when programming the con-
trol panel.
Authorization is followed by a
The door can also be released via a button or an internal reader. This function corresponds with a
normal door strike.
If the door break-in identification is activated, the door may only be released from inside via the input
AC release button. Otherwise an intrusion alarm will be triggered.
- Strike with load current function / Strike with no-load current function
Strike with load current function:
supply fail, the door is locked.
Strike with no-load current function:
power supply fail, the door is unlocked.
- Door strike monitoring contact
If the used door strike is equipped with a monitoring contact, this can be used for monitoring
purposes. The monitoring contact reacts automatically to the door position "Open" or "Closed". The
contact is closed when the door is closed.
- Programming
Depending on the type of door strike being used, program the control panel as a "Strike with no-load
current function or strike with load current function".
The input for the monitoring contact (ST3) can be allocated to a bolt switching group via the
programming of the control panel. A bolt switching group only affects the positive drive condition.
Important note!
Only supply the door strike with power from an external voltage source!
(e.g. U_ext. from the control panel or another external source with 12 V DC or 12 V AC).
Ensure that there is
rating voltage of the door strike and 0V of BUS-2
Should there be a connection in the door strike between
the coil and the monitoring/armature contact, the actuati-
on of the respective input must be connected via a
potential free relay contact.
Mounting and Connection Instructions Door controller module for MB
time-controlled door release.
The catch bolt is unlocked when power is applied. Should the power
The catch bolt is locked when power is applied. Should the
no connection
between 0 V ope-
.
MC
0 V
to ST3
M
1
2
1=NCC
2=NOC