Start-up

On completion of installation and after switching on the operating voltage, the following must be
programmed in the corresponding functions of the control panel:
Allocation of detector groups, authorization granted, blocking time, possible door release time and
door strike functions. For operating units with keypad, the number of digits of the code, the personal
code itself and a hold-up code can also be defined.
The installation mode is then activated at the control panel so that the addresses of the IK3 operating
units/readers can be allocated.
Cover the screw opening with a VdS seal.
10.

Technical data

Rated operating voltage
Operating voltage range
Operating voltage U_BDT for one reader
Current consumption:
-
Module no-load current
-
GBS terminated with 12k1
-
Relay
-
Buzzer
-
Module
, plus all inputs terminated
plus 1 IK3 reader
Detector group inputs:
-
Release contact
-
Glass breakage sensor
-
Bolt switching contact
-
Cover contact - external reader
Contact rating of relays
Interface to readers
Protection category as per EN 60529
Environmental class as per VdS
Operating temperature range
Housing dimensions (W x H x D)
Colour
Mounting and Connection Instructions Door controller module for MB
12 V DC
9 V to 15 V DC
12 V DC, output short circuit-proof,
current-limited at 200 mA max.
< 15 mA (maximum value)
+ 1 mA
+ 17 mA
+ 3 mA
Type 25 mA
3.3 V DC DG, monitored at 12k1±40%
12
12 V DC DG, active LOW
3.3 V DC DG, monitored at 12k1±40%
max. 2 A, 30 V AC/DC, 30 VA
RS-485
IP30
II
-5 °C to +55 °C
118 x 118 x 31 mm
Traffic white (similar to RAL 9016)
V DC DG, monitored at 12k1±30%