WARNING
Connect the appliance to the power
supply.
Contact with live parts may result in electric
shock. Fire hazard due to sparking or over-
load.
§ Only qualified staff may carry out work on
the electrical system.
§ Note and adhere to the following before
connecting to the power supply:
- Applicable local electrical safety regula-
tions.
- Applicable standards and safety instruc-
tions.
- Information on rating plate
[see } Chapter 3.2.1].
§ Do not connect a damaged appliance or
damaged parts (such as connecting
cables) to the power supply.
§ Only qualified staff may replace damaged
parts, e.g. connecting cables.
§ Do not squeeze or bend connecting
cables.
§ Adhere to the minimum requirements for
connecting cables [see } Chapter 3.2].
§ Fuse the appliance in accordance with the
applicable regulations and laws as well as
the specifications issued by AHT
[see } Chapter 8.2].
§ Only connect the appliance to a mains cir-
cuit with protective earthing.
§ Do not use extension cords or multiple
socket strips.
§ Do not damage concealed electrical
parts. Do not drill holes in the appliance
and do not carry out any other work on the
appliance.
NOTICE
Material and property damage due to devi-
ations (voltage, frequency) in the operating
company's electrical network that are not per-
mitted by AHT.
§ The manufacturer is not liable for damage to the
operator's electrical equipment or any resulting
damage.
Material damage due to faulty electrical con-
nection.
§ Load breakers or appliance shut-downs are not
permitted.
§ There must be a continuous power supply.

Appliance connection

Custom deviations possible.
The appliance is connected using a mains plug.
Technical data for interfaces [see } Chapter 3.2].
376840_1_0920
The connection cable is at the back of the appliance.
Appliance connecting cable
NOTICE
Property damage from interruption of the
voltage supply.
Cooling fails.
§ Do not connect the appliance connecting cable to
the power supply for the store lighting.
There is a label tag with a snowflake at the
end of the connecting cable.
The appliance connecting cable is used to supply the
cooling system.
Light connecting cable
There is a label tag with a lamp symbol at the
end of the connecting cable.
The light connecting cable offers the option to switch
the appliance lighting on and off together with the
store lighting (energy saving).
8.2

Fusing

Every electrical connection must be sufficiently fused.
Technical data [see } Chapter 3.2]
WARNING
Faulty/insufficient fuse protection.
Contact with live parts may result in electric
shock. Fire hazard due to sparking or over-
load.
§ Observe applicable local regulations, e.g.
for electrical installation and operation of
the appliances.
§ Observe applicable standards and safety
instructions.
§ Ensure adequate fuse protection.
§ Never operate the appliance without a re-
sidual current device.
§ Never operate the appliance without a
circuit breaker.
§ Never connect more than one appliance to
one fuse.
§ Never connect more than eight lighting
connections to one fuse.
9

Start-up

The appliance may only be started up in the intended
installation room and after checking for completeness.
An appliance may be started up by trained personnel.
WARNING
Damage to the electrical system and/or
the refrigerant circuit.
Start-up | 9