6 | Transport and storage

Press
Deactivate key lock
taneously for 5 seconds.
(Level 2 access)
Level 2 is activated.
Switch on door heat-
ing
Switch off door heat-
ing
5.5.8

Alarm

Display alarm
An error code appears on the display as a flashing in-
dication alternating with the internal temperature.
The symbol
appears on the display.
Troubleshooting measures for the occurrence of alarm
indicators; see [see } Chapter 10.3].
Error code
Bus error
Bus address collision
Sensor error F1
Sensor error F2
Sensor error F3
alternately Defrost system error
/
Time/date error
Data memory fault
Flashing temperat-
Overtemperature alarm
ure value
Communication fault, controller/
inverter
Overcurrent at inverter fan out-
put
Compressor start error
Compressor overcurrent
Inverter overtemperature
Inverter internal error
Inverter supply voltage outside
limits
Acknowledge alarm
The error code and the symbol
knowledged.
The error code and symbol
ror is rectified.
6
Transport and storage
a) After delivery, check the appliance for transport
damage.
50 / 788
and
simul-
or
press briefly .
appears on the display.
or
press briefly .
goes out on the display.
Meaning
CANNOT be ac-
are shown until the er-
b) In the event of damage to the appliance, promptly
contact the maintenance service
[see } Chapter 12.4].
WARNING
Damage to the refrigerant circuit.
Flammable refrigerant can escape and cause
an explosive gas/air mixture.
§ Do not expose the appliance to temperat-
ures higher than 70°C (158°F) during
transport and storage.
§ Ensure good ventilation.
§ Observe safety notices and warnings for
appliances with flammable refrigerants
[see } Chapter 2.2].
§ In the event of damage to the appliance,
promptly contact the maintenance service
[see } Chapter 12.4].
Transport of the appliances with indus-
trial trucks.
Risk of injury to persons in the event of a colli-
sion.
§ Observe transport routes for industrial
trucks.
§ Secure transported goods.
§ Only trained personnel may operate in-
dustrial trucks.
§ Note the centre of gravity of the appliance
for safe lifting of the load with the forklift.
Information is provided on the front and
back of the appliance packaging.
NOTICE
Material damage caused by transport and
storage.
§ Transport and store the appliance in a stable oper-
ating position (horizontal alignment).
§ If the unit was tilted during transport, wait at least
two hours before starting it up.
§ On delivery, ensure full accessibility to the installa-
tion point (observe clearance heights, clearance
widths, installation space height, sufficient turning
radii).
§ Do not store the appliance outdoors.
7

Unpacking

Responsibility
– Qualified staff
a) Check the appliance for damage before and during
unpacking.
b) In the event of damage to the appliance, promptly
contact the maintenance service
[see } Chapter 12.4].
AHT Cooling Systems GmbH | en