  • DEUTSCH, seite 3
AHT Cooling Systems GmbH | en
– Error code
– Acoustic alarm (optional)
Further remote monitoring options can be obtained
from your maintenance service [see } Chapter 12.4].
11

Maintenance

Inspection tasks by operating personnel
Control tasks
quency
Proper condition of
ongoing
appliances
Foreign objects in
ongoing
goods area
Closed doors
ongoing
Damage glass ele-
ongoing
ments /doors
Puddles in front of/
underneath appli-
daily
ance (defrosting/
condensation water)
Function of the self-
closing mechanism
ongoing
on the doors
Sticker on the appli-
Weekly
ance
several
Interior temperature
times a
day
Proper loading with
ongoing
goods
Contamination of the
appliance, including
daily
glass
Food and packaging
daily
residues
Floor (surroundings
daily
of the appliance)
Door seal damage
Weekly
11.1

Cleaning

Reasons for regular and thorough cleaning (basic
cleaning/main cleaning):
– Ensuring the necessary hygiene. Always keep the
goods area in a clean condition.
– Lowest possible energy consumption.
– Maintaining trouble-free operation.
– Extension of the service life of the appliance.
376840_1_0920
Fre-
description
[see } Chapter 1.4]
[see } Chapter 10]
[see } Chapter 1.4]
[see } Chapter 10]
[see } Chapter 1.4]
[see } Chapter 2.3]
[see } Chapter 2.3]
[see } Chapter 10]
[see } Chapter 4.1]
[see } Chapter 10]
[see } Chapter 4]
[see } Chapter 4]
[see } Chapter 5.1]
[see } Chapter 10.1]
[see } Chapter 11.1.1
]
[see } Chapter 11.1.1
]
[see } Chapter 11.1.1
]
[see } Chapter 11.1.1
]
WARNING
Damage to the electrical system and
refrigerant circuit due to the use of
steam and high-pressure cleaners.
Contact with live parts may result in electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Fire haz-
ard due to sparking or overload.
§ Do not use steam or high-pressure clean-
ers for basic cleaning.
§ Follow the instructions for main cleaning.
Electrostatic discharge and spark
formation with flammable refrigerant.
On a damaged / leaking refrigerant circuit,
sparks may ignite escaping refrigerant. Fire
hazard.
§ Use a damp cloth or sponge to remove
condensation water.
§ Do not use dry cloths or sponges to dry
the appliance.
§ Do not operate any electrical devices (e.g.
wet vacuum cleaners) inside the cooling
compartment that do not correspond to
the design recommended by the manufac-
turer. Appliances with explosion protection
markings [see } Chapter 1.3] are permit-
ted.
CAUTION
Heavy appliance parts.
Hands may become trapped.
§ Wear protective gloves.
Material breakage.
Falling hazard. Impact hazard due to the pos-
sibility of falling goods. Cuts.
§ Do not climb onto or into the appliance.
Low temperature.
Frostbite to skin.
§ Wear protective gloves when cleaning.
Safety when handling glass [see } Chapter 2.3].

11.1.1 Basic cleaning

Responsibility
– Operating personnel
Cleaning interval
– During operation
– As required
– With cooling function switched off
– At least every six months
– As required