AHT Cooling Systems GmbH | en
3

Product description

3.1

General information

AHT products comply with EU Regulation 1907/2006
(REACH) on the Registration, Evaluation, Authorisa-
tion and Restriction of Chemicals.
3.2

Technical data

Important technical data can be found on the power
rating plate [see } Chapter 3.2.1].
Parameter
Value
See →Appliance model over-
External dimensions
view
See →Appliance model over-
Appliance weight
view
Refrigerant
Propane (R-290)
Refrigerant per refri-
≤ 150 g
gerant circuit
Ozone depletion po-
tential (ODP)
0
Propane (R-290)
Global Warming Po-
tential (GWP)
3
Propane (R-290)
Airborne noise emit-
ted/emission sound
< 70 dB(A)
pressure level
M-package temper-
ature class (product
temperature class)
L1
pursuant to EN ISO
23953-2
Legally required in-
formation about the
https://eprel.ec.europa.eu/
model
Maximum load
Parameter
Value
Display shelf/pieces 26 kg
Mesh basket/pieces 26 kg
Bottom shelf/pieces 26 kg
Bus system
Depending on the electronic controller
Electronic controller AHT (Secop GP)
– [see } Chapter 5.3.5]
Electronic controller Carel
– [see } Chapter 5.4.3]
Electronic controller AHT (Wurm)
– [see } Chapter 5.5.6]
Electrical connection
rated voltage
220 – 240 V
rated frequency
50 Hz/60 Hz
– Power supply
unit and light
376840_1_0920
Plug types
National versions
Connecting cable
3-pin cable
Minimum cross-sec-
tion for appliance
1.5 mm²
connecting cables
Minimum cross-sec-
tion for light connect-
1.0 mm²
ing cables
Fusing
[see } Chapter 8.2]
Type
Rated
Fault
current
current
[A]
[mA]
Circuit breaker (LS/CB)
10
-
-
(1 appli-
ance)
10
-
-
(light)
Residual current circuit breaker (FI/RCCB/GFCI)
G (short-time delay)
A (pulse current-sensitive)/
40
30
F (mixed frequency-sensitive)/
B (universal current-sensitive)
Residual current circuit breaker with overcurrent pro-
tection FI-LS/RCBO (alternative to RCCB and CB)
G (short-time delay)
10
A (pulse current-sensitive)/
30
(1 appli-
F (mixed frequency-sensitive)/
ance)
B (universal current-sensitive)
G (short-time delay)
10
A (pulse current-sensitive)/
30
(light)
F (mixed frequency-sensitive)/
B (universal current-sensitive)
Custom deviations possible.
More information: Maintenance services
[see } Chapter 12.4]
Subject to technical changes.
3.2.1

Rating plate and serial number

Observe the information on the rating plate.
The rating plate is a sticker located at the top right in-
side the appliance.
Information on rating plate
– Appliance name and type
– Serial number
– Climate class*
– Rated voltage and frequency
– Rate current and consumption
– Refrigerant and quantity used
– Net content
– Date of manufacture
– and further technical data
Product description | 3
Tripping
charac-
teristic
C (slow-
acting)
C (slow-
acting)
-
C (slow-
acting)
C (slow-
acting)