Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Standard Installation - AEG DDLT PinControl 13 Bedienung Und Installation

Vorschau ausblenden Andere Handbücher für DDLT PinControl 13:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation

Taps
Use appropriate pressure taps. Open vented taps are not
permissible.
Thermostatic pressure valves must be suitable for hydrau-
lically controlled instantaneous water heaters.
Note
Never use the shut-off valve in the cold water inlet
to reduce the flow rate. It is intended for shutting off
the appliance.
Permissible water line materials
◦ Cold water inlet pipe:
Pipes made from galvanised steel, stainless steel,
copper or plastic
◦ DHW outlet line:
Pipes made from stainless steel, copper or plastic
Material losses
!
If plastic pipework systems are used, take into ac-
count the maximum inlet temperature and the max-
imum pressure (see chapter "Specification / Data
table").
Flexible water connection lines
» If the appliance is installed with flexible water
connection lines, ensure that the pipe bends with
bayonet fittings do not become twisted inside the
appliance.
» Secure the back panel at the bottom with two addi-
tional screws.
10. Installation

10.1 Standard installation

◦ Electrical connection from above; installation on un-
finished walls
◦ Water connection on unfinished walls
For further installation options, see chapter "Alternative
installation methods":
◦ Electrical connection from below on unfinished walls
◦ Electrical connection on finished walls
◦ Connecting a load shedding relay
◦ Water installation on finished walls
◦ Water connection on unfinished walls for appliance
replacement
20
Opening the appliance
» Open the appliance by releasing the snap lock.
» Remove the back panel by pressing the two locking
tabs and pulling the lower section of the back panel
forwards.
Preparing the power cable
160
≥ 30
Fitting the wall mounting bracket
» Mark out the holes for drilling using the installation
template. If the appliance is to be installed with water
connections on finished walls, also mark out the fix-
ing holes in the lower part of the template.
» Drill the holes and secure the wall mounting bracket
with 2 screws and 2 rawl plugs (screws and rawl
plugs are not part of the standard delivery).
» Fit the threaded stud provided.
» Fit the wall mounting bracket.

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis