INSTALLATIoN
Installation
1 Condensate and cable entry (top)
2 Condensate and cable entry (back)
Condensate drain hose in cable entry (back)
f Pull the condensate drain hose back into the control panel.
f
f Use a screwdriver, for example, to poke a hole in the grom-
f
met of the condensate entry.
f Route the condensate drain hose through the grommet.
f
Condensate drain hose in exhaust air connection
WARNING Injury
f Ensure that no risk of slipping due to wet conditions
f
or ice formation occurs on adjacent footpaths and
driveways at low temperatures.
Note
If the exhaust air outlet is installed in the roof, the con-
densate should not be drained through the "Exhaust air"
connection.
f Pull the condensate drain hose back into the control panel.
f
f Reach into the appliance through the exhaust air connection.
f
f Pull the condensate drain hose into the exhaust air chamber.
f
f Route the condensate drain hose through the "Exhaust air"
f
connection to the outside of the building.
Material losses
!
Routing the condensate drain hose to the outside through
the exhaust air connection can result in traces of conden-
sate on the external cladding of the building.
5.5

Air ducts

Material losses
!
Never connect cooker hoods or dryers to the ventilation
system.
Material losses
!
During installation, ensure that no metal swarf enters
the pipework. However, should this occur, remove this
debris, otherwise the fans may be damaged.
26
| VRL-C 300/625/870
5.5.1 Insulation against condensation
1
Material losses
!
When warm air meets cold surfaces, condensation can
2
result.
f For outdoor air and exhaust air ducts, use vapour
f
proof thermally insulated pipes.
f If the supply and extract air ducts are routed
f
through unheated rooms, insulate these ducts as
well.
5.5.2 Connecting air ducts to the appliance
f Push the air duct onto the air connection.
f
5.5.3 Overflow apertures
Living rooms and bedrooms are only supplied with air. Air is only
extracted from rooms where odours and moisture are generated.
Ensure an unimpeded overflow and consequently air balancing.
Install ventilation grilles in internal doors or walls, or enlarge the
air gap beneath the door to ≥ 8 mm.
5.5.4 Cleaning apertures
f Fit cleaning apertures when installing the air ducts, so
f
that the air ducts can be inspected and cleaned at regular
intervals.
5.6

External cover

3
4
1 External cover
2 Bird guard
3 Screw
4 Sealing tape
5.7
Option: CO
Note
Never position the sensor in the supply air flow or close
to windows or external doors.
5.8

Option: Motion sensor

f Install the motion sensor in an appropriate place.
f
2
or VOC sensor
2