8.6

Selection of anchors

8.6.1 Hilti injection anchor
Quality of concrete Normal armouring
subject to alterations!
Hilti injection anchor
concrete floor
type of dowel
drilling depth (mm)
min.anchorage depth (mm)
component thickness (mm)
diameter of bore (mm)
attachment thickness (mm)
turníng moment (Nm)
Total length (mm)
Thread
piece number
Observe necessarily the installation description of the dowel manufacturer.
Use longer dowels with version with floor pavement and tiles.
It is possible to use equivalent injections dowels (with license) of other manu-
facturer but observe their regulations.
100
POWER LIFT HL 2.50 NT
without floor pavement (tiles)
HIT-V-5.8 M16x200
Art.Nr.956437
h
144
o
h
144
ef
h
min.180
min
d
0
t
fix
T
inst
I
200
M
a
b
c
d
e
f
g
OPI-POWER LIFT HF 3S 5000 - HYMAX HF 3S 5000-V1.1-DE-EN-FR-ES-IT
18
23
80
16
4
8
10
12
14
16
28

Werbung