Installing the Pump

Typical installation is shown only as a guide for selecting and
installing system components. Contact your Lincoln
Industrial representative for assistance in designing a
The pump was tested in light weight oil which was left in to
protect the pump from corrosion. Flush the pump before con-
necting it to the system to prevent contamination of the grease
with residual oil.
manifold (37). A normally closed ON/OFF Solenoid Valve (35)
is also integrated into the manifold and will start or stop the
pump operation.
1. Mount the pump securely on the drum cover so that it
cannot move or vibrate during operation.
2. Attach hydraulic supply line to the Inlet and return line to
the Tank ports.
3. Connect material supply line to the pump outlet. Plug
the unused outlet on opposite side of the pump.
4. Install high pressure shut-off valve in the material supply
line. (Required)
5. Connect 24 VDC power supply to the solenoid valve (35).
See Illustration #1. Use connector plug (36) supplied
with the pump.
Illustration 4
* Included in Spacer Kit 272013
Mount the pump securely on the drum cover. Failure to do so
could result in personal injury and equipment damage.
Do not exceed 450 PSIG (32 bar) working hydraulic
pressure. Use high pressure components to reduce risk of
or on the skin. All accessories connected to the pump outlet
must have at least 5,000 PSIG (350 bar) minimum hydraulic
operating pressure. All accessories connected to the pump
inlet must have at least 3,500 PSIG (241 bar) minimum work-
ing pressure.
Form 403750
FlowMaster™ Rotary Driven Hydraulic Pump

Operation

All pumps are factory set at 300 PSIG (20.7 bar) working inlet
not attempt to change the settings.
1. Shut off the material supply line valve.
2. Turn on the hydraulic pressure.
On/Off valve.
4. Prime the pump by slowly opening the shut-off lubricant
supply line valve. Make sure that all air has been
achieved.
factory preset and are not user adjustable.
Do not exceed maximum operating temperature of the
dry of lubricant. A dry pump quickly speeds up, creating friction
heat, which can damage the seals. Monitor the supply
Setting the Pump Manifold Pressure and
Flow Controls
PSIG (20.7 bar) are factory preset and are not adjustable.

Maintenance and Repair

Relieve pressure from the pump and supply lines before
servicing or repairing the pump, to reduce the risk of an injury
Always use Lincoln Industrial parts for service and repair.
Crankcase Oil Service Interval Recommendations
Check the oil level after every 750 hours of machine operation,
or every month.
Change the oil after every 2,000 hours of machine operation or
every year.
Use SAE 10W30 motor oil in all units used in an ambient
temperature between 150 to -40°F. For ambient temperatures
between 50 to -70°F, use Mobil Arrow HFA Low Temperature
oil.
Oil level should be at dot on dipstick (middle of crankshaft)
Do