Herunterladen Inhalt Inhalt Diese Seite drucken

Master/Slave-Operation; Connection With The Mains; Operation - EuroLite 36x1W RGB Bedienungsanleitung

Led ip par led outdoor floorspot
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Master/Slave-Operation

The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the EUROLITE LED IP PAR 36x1W RGB/LED IP PAR 12x3W TCL you can find a DMX
input plug and a DMX output connector, which can be used for interconnecting several devices.
Choose the device which is to control the effects. Set the desired Master-mode on the master-device. This
device then works as master-device and controls all other slave-devices, which are to be connected to the
master-device via a balanced microphone lead. Connect the DMX out connectors with the DMX input plug of
the next device.
Set the DMX start address 001 on every slave-device.

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

OPERATION

After you connected the spot to the mains, the EUROLITE LED IP PAR 36x1W RGB/LED IP PAR 12x3W
TCL starts running.
The LED display lights up and you can choose the desired mode via the buttons MODE, ENTER, UP and
DOWN.
Attention: After every 8 LED IP PAR 36x1W RGB/LED IP PAR 12x3W TCL, the fixtures must have a
renewed connection with the power mains.
Please make sure that open contacts are closed with the enclosed caps in order to avoid humidity
and dirt in the device.
The device has two operating modes. It can be operated in Stand Alone or in DMX-controlled mode.
- STAND ALONE-MODE
Setting Solid Colors
Setting LED Colors (0 – 100%)
Internal Programs
- DMX MODE
International
L
N
20/23
00063704.DOC, Version 1.1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

12x3wtcl

Inhaltsverzeichnis