Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Determinations - EuroLite 36x1W RGB Bedienungsanleitung

Led ip par led outdoor floorspot
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPERATING DETERMINATIONS

This device is a fixed general purpose luminaire. This product is only allowed to be operated with an
alternating voltage of 230 V, 50 Hz.
This device is jet-proof (IP65) and therefore qualified for indoor and outdoor use. In order to maintain this
protection grade after opening the housing, any rubber sealings must be examined for damages and always
be correctly installed.
For outdoor use, the installer must always make sure to connect a rubber cable H05RN-F or HO5RR-F. For
installations in the ground, an underground power cable NYY must be used!
All valid instructions concerning the installation of cables outdoors or in the ground must be adhered!
The ambient temperature must always be between -25° C and +45° C. Keep away from direct insulation
(particularly in cars) and heaters.
The maximum relative humidity is 100 % with an ambient temperature of 25° C.
This device must only be operated in an altitude between -20 and 2000 m over NN.
This device is designed for professional use.
Do not shake the device. Avoid brute force when installing or operating the device.
When choosing the installation-spot, please make sure that the device is not exposed to extreme heat,
moisture or dust. There should not be any cables lying around. You endanger your own and the safety of
others!
The maximum ambient temperature T
= 45° C must never be exceeded.
a
The F-symbol means: this device can be installed on normal inflammable surfaces.
Never use the device during thunderstorms. Over voltage could destroy the device. Always disconnect the
device during thunderstorms.
- - -m
The symbol
determines the minimum distance from lighted objects. The minimum distance
between light-output and the illuminated surface must be more than 0.1 meters.
This device is only allowed for an installation via the mounting bracket. In order to safeguard sufficient
ventilation, leave 50 cm of free space around the device.
The housing must never touch surrounding surfaces or objects.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
fixture.
Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly
fastened.
Operate the device only after having become familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional operation!
Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported. Make sure that you pack the device in
the original state.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
Never remove the serial barcode from the device as this would make the guarantee void.
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, crash etc.