4.
The stove must be connected to a chimney with a diameter that conforms
to the specifications in Table 1 of this installation manual. Use of a chimney
with a larger diameter that does not exceed 150 mm is permitted, provided
that it conforms with the indicated foced draught.
5.
Refer to the local /national provisions, regulations, and legislation in order
to verify the possibility of positioning the draught valve in the chimney
channel.
6.
Do not install electric cables down the chimney or near it.
7.
The fireplace must be smoke-tight.
8.
The chimney must be vertically installed in such a way that no flue gas blocks
occur. If, however, a part of the chimney needs to be horizontally installed,
the length of the horizontal part should be no more than 2 m and must
slope by at least 5° in the direction of the combustion gas exhaust pipe. See
table 1.
9.
We strongly advise against installing a horizontal pipe in the flue. Please
note: There may be local and national rules and regulations in place that
expressly forbid the use of a (partially) horizontal flue. Always follow these
rules & regulations. You can find an overview of the number of curves and
T-pieces, the chimney height and the required inner diameter of the flue
pipes in Table 1.
10.
We recommend fitting a T-piece with an inspection hatch on the underside
directly on the stove connection channel. Should a horizontal part be fitted
on the stove connection channel, immediately after this horizontal part, we
recommend fitting a T-piece with an inspection hatch on the lower side.
Any condensation or solids will be collected in this T-joint and can removed
by opening the inspection hatch. The inspection hatch must be smoke and
water tight.
11.
The chimney outlet must be equipped with an approved cover.
12.
The fireplace and stove must be easily accessible for inspection and cleaning
purposes.
13.
The stove cannot be used to support the chimney/flue pipe.
14.
If an existing flue pipe/chimney is used, it must be cleaned by an author-
ised chimney cleaning company before installing the stove. The presence of
soot and combustion residue can reduce the flow up an existing flue pipe/
chimney and cause the stove to malfunction. The accumulation of soot and
other foreign bodies can trigger hazardous situations. If an existing flue
pipe/chimney has a diameter in excess of 150 mm, it must be adapted to suit
a pellet stove by fitting a pipe inside the existing chimney.