7. Operating instructions

7.1 Domestic water circulation

The domestic water circulation system is used to provide a constant supply of hot water to the taps and to flush the domestic water
pipes (        g rowth of legionella). Please ensure you comply with the relevant technical regulations and guidelines.
A check valve is installed on the pressurised side of the circulation pump on the domestic water side in order to prevent unwanted circulation. The con-
troller can be used to control the domestic water circulation. The factory setting must be dependent on the object adapted.
DN32 backflow preventer
in the domestic water circulation
with 2" seal
The illustration shows the installation position
and the flow direction of the return inhibitor
33