may damage the battery.
In order to preserve the operating life of the
battery, it should be recharged at least once
every 3 - 5 months, irrespective of the amount of
usage.

10.Replacing the lamp

Important! The lamp must be switched off.
Proceed as follows to replace the lamp.
1. Using both hands, squeeze the lamp cover
(Fig. 1/Item 6) together slightly from the sides,
then pull the cover off.
2. Turn the lamp socket anti-clockwise.
3. Replace the lamp with the same style of bulb
(i.e. 12 V/0.3 A).
4. To install the new lamp, proceed in reverse
order.
5. Snap the light cover (Fig. 1/Item 6) back on.
11. 12-volt compressor
11.1 Filling tires
Note! Use a tire pressure gauge to check the actual
tire pressure at the nozzle. Observe the information
in the vehicle's owner manual concerning the filling
of tires.
1. Remove the valve cap from the valve.
2. Push the connector piece of the compressor all
the way down over the valve (Fig. 2/Item 1).
3. Secure the connector piece by flipping back the
locking lever on top of the connector (Fig. 2/Item
2).
11.2 Filling air mattresses, etc.
Important! Because of the material composition of
air mattresses, rubber rafts, etc., obtaining an exact
air pressure read-out is not possible. Therefore, pay
special attention to ensure that you do not overfill
these objects, as they will burst!
¼
Select the appropriate adapter and insert it into
the connector piece of the air hose.
Adapter 1 (Fig. 3/Item 1): for air mattresses
Adapter 2 (Fig. 3/Item 2): for sporting balls
Adapter 3 (Fig. 3/Item 3): for beach balls
¼
Secure the connector piece by flipping back the
locking lever on top of the connector (Fig. 2/Item
2).
12
17.04.2003
9:59 Uhr
Seite 12
11.3 Starting up the compressor
Important! Please read the bulleted items listed
under „1. Important Notes" prior to starting up the
compressor. Ensure that the compressor cools
down for 10 minutes after it has run for 10 minutes.
¼
Check the pressure gauge (Fig. 4/Item 2) prior to
switching on.
¼
To switch on, flip the ON/OFF switch
(Fig. 4/Item 1) to „I".
¼
To switch off, flip the ON/OFF switch
(Fig. 4/Item 1) to „0".

12.Maintenance and care

¼
Be sure to switch off the energy station and
disconnect all cables from the unit whenever you
perform any cleaning or maintenance work.
¼
As far as possible, use only a soft dry cloth
without any aggressive solvents to clean the
surface. If absolutely necessary, use a slightly
dampened rag to remove dirt.
13. Repair
Should the tool experience problems beyond those
mentioned above, let only an authorized professional
or a customer service shop perform an inspection.
14. Disposal
The tool, accessories and packaging should be
disposed of in an environmentally-friendly fashion.
Plastic parts are coded for purposes of separation
when recycling.