Herunterladen Inhalt Inhalt Diese Seite drucken

tau D770M Installationsanleitung Seite 18

Steuerkarte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
ELECTRIC LOCK
11
OPERATION
SENSITIVE EDGE
12
SELECTION
* It is necessary to run the SETUP stroke if you modify the DIP.
** It is necessary to run the SETUP stroke if you turn the DIP from ON to OFF
IMPORTANT:
Each pair of terminals attached to an NC contact that is not in use must be short-circuited in order to
ensure the proper operation of the board.
The door's earthing system must comply with current standards. The manufacturer will accept no li-
ability for any damage deriving from failure to comply with this requirement.
7. PROGRAMMING INSTRUCTIONS (SETUP)
If a transmitter has been previously programmed, it can be used to perform the following procedure.
Otherwise, connect a Key Switch or a NO Pushbutton to the AP/CH wire terminals on the controller.
DOUBLE SWING GATE -
1
Press and hold down for at least 5 seconds P1 and P2 buttons to activate the programming mode;
2
Leds DL7 + DL8 begin to flash quickly and the 2 wings open;
f the automation closes instead of opening, stop the gate travel by temporarily disconnecting
the voltage. Invert the phases of the motor that closes (terminals 4-6 for M1, terminals 7-9
for M2) and resume the procedure from the beginning after having given voltage.
3
Once opening is complete, press AP/CH button or the remote control: both leaves will stop;
4
Press AP/CH button or the remote control: the leaf #2 will close at standard speed;
5
Press AP/CH button or the remote control when the leaf should start to decelerate;
6
When the leaf is completely closed press AP/CH button or the remote control (leaf #2 program-
ming completed);
7
Press AP/CH button or the remote control: the leaf #1 will close at standard speed;
8
Press AP/CH button or the remote control when the leaf should start to decelerate;
9
When the leaf is completely closed press AP/CH button or the remote control (leaf #1 program-
ming completed);
10 The green led DL7 will flash every 4 sec. (programming completed and saved).
SINGLE SWING GATE -
1
Press and hold down for at least 5 seconds P1 and P2 buttons to activate the programming mode;
2
Leds DL7 + DL8 begin to flash quickly and the 2 wings open;
f the automation closes instead of opening, stop the gate travel by temporarily disconnecting
the voltage. Invert the phases of the motor that closes (terminals 4-6 for M1, terminals 7-9
for M2) and resume the procedure from the beginning after having given voltage.
3
Once opening is complete, press AP/CH button or the remote control: the leaf will stop;
4
Press 4 times AP/CH button or the remote control: the leaf will close at standard speed;
5
Press AP/CH button or the remote control when the leaf should start to decelerate;
6
When the leaf is completely closed press AP/CH button or the remote control (leaf programming
completed);
7
The green led DL7 will flash every 4 sec. (programming completed and saved).
DIP 8 OFF (2 motors operation) - DIP 9
GATE 2 WINGS -
1
Press and hold down for at least 5 seconds P1 and P2 buttons to activate the programming mode;
2
Leds DL7 + DL8 begin to flash quickly and the 2 wings open;
f the automation closes instead of opening, stop the gate travel by temporarily disconnecting
the voltage. Invert the phases of the motor that closes (terminals 4-6 for M1, terminals 7-9
for M2) and resume the procedure from the beginning after having given voltage.
On
Operation of the electric lock for the entire opening and closing time
Impulsive operation of the electric lock: at each opening, the electric lock
Off
works for a short moment.
On
RESISTIVE SENSITIVE EDGE (terminal no. 15)
RESISTIVE EDGE - potential free contact N.C. (terminal no. 15)
Off
Note: if not used, keep the DIP in the OFF position.
DIP 8 OFF (2 motors operation) - DIP 9
DIP 8 ON (1 motor operation) - DIP 9
in ON (Soft-Stop function enabled):
in ON ( Soft-Stop function enabled):
in OFF (Soft-Stop function disabled):
18

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis