Herunterladen Inhalt Inhalt Diese Seite drucken

Obstacle Detection; Optional Accessories - avidsen V300 Bedienungsanleitung

Mit zylinderantrieb; für flügeltore
Vorschau ausblenden Andere Handbücher für V300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 134
E - OPERATION

2.4 - OBSTACLE DETECTION

During their movement, the panels may encounter
an obstacle.
• For safety purposes, if the motors are under
too much strain (the force is adjustable; see
"Motor Force" in the settings), the gate stops and
releases the pressure and the flashing light emits
double flashes for 30 seconds. The flash can be
stopped by pressing a command.
• On activating a command (the same one that was
used to start the movement), the gate starts to
move in the opposite direction.
• If an obstacle is detected during closure and
the operating mode is "automatic closure" or
"collective", the gate will open again and the time
delay will start again.
• If the gate has a large area of wind resistance
(solid gate), this can trigger obstacle detection in
windy weather. In this case, increasing the motor
force is recommended.
2.5 - MANUAL MOVEMENT
Note: When the actuators are disengaged from
the gate, the gate may be set in motion by the wind
or an external push. It is therefore important to be
careful or block the gate to avoid any risk of injury.
Just remove the pin and raise the operator arm.
The gate can therefore be opened manually during
a power failure.
EN
34

3 - OPTIONAL ACCESSORIES

Element
Additional remote control
www.avidsenstore.com
Additional set of photocells
www.avidsenstore.com
Key switch:
www.avidsenstore.com
Backup battery
Solar power kit
Reference
114253
114359
104258
580293
114373

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

114165

Inhaltsverzeichnis