D - BEGINNING OPERATION
Note:
Operation
adjustments made by a person qualified to
work on this equipment because the active
parts are accessible.
1 - SETTINGS INTERFACE
Indicators
• L0 = Green LED (switched off when the card is
on standby)
• L1 to L4 = Red LEDs to display information
concerning settings, events (or errors) or battery
status.
Buttons
PROG = Enter or exit settings menus.
"-" / "+" = Select a menu item, set a value, navigate
the event log.
OK = Enter sub-menus, confirm a setting, view the
battery voltage or history of events, enter manual
control mode.
Important notes:
• You can do a short press on a button (hold the
button down for less than 1 second) or long press
(hold the button down for 3 seconds). In the
following, when we write:
- "Press the button", this means a short press
(one press) on this button.
- When we write "long press", you must press the
button for 3 seconds.
• In the instructions below, the operations to be
performed with the buttons will be described
from MENU 0. It's the display menu that appears
just after the power has been switched on for
example, just after the gate has moved (before
standby) or even when the card is on standby (in
this case, the green LED L0 is switched off).
• To be sure of being on MENU 0 of the display,
press on PROG 2 or 3 times and the green LED
should be switched on (only the green LED).
When the user performs no action on a button
for 15 seconds, the system automatically goes
back to MENU 0.
EN
22
must
be
begun
and

2. QUICK SETTINGS

2.1. SELF-LEARNING
Self-learning enables the card to learn how far
the gate moves. Before starting this step, the gate
must have fixed stops at the end of closing and
end of opening to stop its movement.
Self-learning starts with a closing cycle. If this is
not the case, stop the learning cycle by pressing
the "OK" button
and reverse the motor's connections.
Self-learning procedure:
• The flashing light starts (1 flash per second).
• Phase 0: Detection of the closing stop; the gate
closes up to the closing stop.
• Phase 1: Measurement of opening length, the
gate opens up to the opening stop.
• Phase 2: Measurement of the closing length; the
gate closes up to the closing stop.
Starting self-learning:
• Press 2 or 3 times on PROG and the green LED
should be switched on (only the green LED)
• Long press on the "+" button and self-learning
will start.
Once self-learning has finished, you can use your
gate motor drive.
If self-learning has stopped, see the table below.
Resolve the problem with the table and restart self-
learning.
If you would like to change the settings on your
motor drive, visit the "ADVANCED SETTINGS"
paragraph