Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - VOLTCRAFT 124601 Bedienungsanleitung

Digital-multimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical Data

Symbol . . . . . . . . . . . . . . . . . . . . . . . . .6000 counts
Measuring rate . . . . . . . . . . . . . . . . . . .Approx. 3 measuring operations/second
measuring line length . . . . . . . . . . . . .Approx. 90 cm each
Measuring impedance . . . . . . . . . . . . .>10MΩ (V range)
Operating voltage . . . . . . . . . . . . . . . .9V block battery
Working conditions . . . . . . . . . . . . . . .0 to 30°C (<75%rF), >30 to 40°C (<50%rF)
Operating altitude . . . . . . . . . . . . . . . .max. 2,000 m
Storage temperature . . . . . . . . . . . . . .-10°C to +50°C
Weight . . . . . . . . . . . . . . . . . . . . . . . . .Approx. 380 g
Dimensions (LxWxH) . . . . . . . . . . . . . .185 x 91 x 43 (mm)
Over-voltage category . . . . . . . . . . . . .CAT III 1,000 V, CAT IV 600 V, contamination degree 2
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)).
The accuracy is valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than
75 %, non-condensing. Temperature coefficient: +0,1 x (specified accuracy)/1°C
Direct voltage
Range
600 mV
6 V
60 V
600 V
1,000 V
Overload protection 1,000 V; Impedance: 10 MΩ
Alternating voltage
Range
6 V
60 V
600 V
750 V
Frequency range 45 – 400 Hz; Overload protection 750 V
VC830: Effective average (RMS) at sinus voltage
VC850TrueRMS: Crest factor: max. 3.0
Permissible display error with an open measuring input: 2 counts
Permissible display error with a short-circuited measuring input: 20 counts
Accuracy
±(0.5% + 8)
±(0.6% + 8)
±(0.8% + 8)
Accuracy
±(1.0% + 8)
±(1.3% + 5)
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V