b-intense
infrared cabins: transportation, storage and installation
®
Transportation of b-intense
The b-intense
®
infrared cabin must be transported on pallets by a transport company suitable for pallet transport and fragile goods. In case
of visible damage to the packaging, please contact the b-intense
Storage of the b-intense
The storage of the b-intense
b-intense
quality check quickly. The stored product must remain on the pallet until the final installation.
®
Please consider the following recommendations for installation:
› Make sure that the floor surface for siting the cabin is flat and level. Minor irregularities in the surface can be offset by the adjustable
feet fixed to the underside of the cabin base.
› The b-intense
infrared cabin must be placed indoors.
®
› The space between the wall and the cabin of at least 2 cm has to be considered.
› The distance from the cabin roof to the ceiling above should be at least 10 cm.
› The ambient temperature of the b-intense infrared cabin should be at least 18° C (Room temperature) and at maximum 35° C.
› The optimal humidity should not exceed 70%. If this is not possible, suitable ventilation of the space to be used must be arranged.
› The cabin must be protected from any direct water spray and from wet or damp from the floor. Condensation in the room where the
cabin is sited must be prevented and adequate ventilation must be ensured.
Please observe the following safety-relevant parameters:
› The minimum distance of the radiators to the ceiling is 50 cm.
› The minimum distance of the radiator to the floor is 10 cm.
› The horizontal minimum distance of the back-heater to burning materials is 10 cm.
› The horizontal minimum distance of the front-heater to burning materials is 30 cm.
› The minimum distance between two adjacent radiators is 20 cm.
› The minimum cabin height is 190 cm.
infrared cabin
®
infrared cabin
®
infrared cabin should be as short as possible and not exceed one month in order to be able to complete the
®
®
office immediately. The cabin must not be assembled until release.
35