Herunterladen Inhalt Inhalt Diese Seite drucken

Pilz PKB-M Bedienungsanleitung Seite 44

Elektronische bremssysteme
Vorschau ausblenden Andere Handbücher für PKB-M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

www.dplusa.fr
Operation
Process
Data
START
XXXXXXXX
E-Halt
XXX
E-Reset
XXXXXX
Slave
XXX
ext.Temp
XXX
int.Temp
XXX°C
Contrast
XXXX#
14
DETECTION ET AUTOMATISME - 17 Rocade de la Croix St Georges - 77600 BUSSY ST GEORGES - Tél : 01.64.66.90.00 - Fax : 01.64.66.98.01 - mail : infos@dplusa.fr
Downloaded from
www.Manualslib.com
Process data
Reset contact monitoring
XXXXXXXX Dynamic: A braking process can be interrupted by opening
the reset contact
Static: A braking process cannot be interrupted again by
opening the start contact.
Braking with overtemperature
XXX
Off: A braking process is interrupted by overtemperature, the
brake goes into fault.
On: A braking process continues despite overtemperature,
after that the brake goes into fault.
Error-reset
XXXXXX Auto: Fault is reset automatically
Manuel: Fault must be reset manually (press ESC and ENTER
simultaneously).
Master-Slave operation
XXX
Off: Stand-Alone-operation
On: Operation with Slave-brake (symmetrical braking)
Motor temperature monitoring
XXX
Off: without motor temperature monitoring
On: The value of the connected PTC-thermistor at the
terminals Z31 and Z32 is monitored and if one of the internally
programmed thresholds is exceeded, the braking operation and
the motor enable are locked.
Heatsink limit temperature
XXX
Maximum heatsink in
LCD contrast
XXXX
LCD contrast value, can be saved (retentive) in this menu
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
manuals search engine
o
C
PKB-M, PKB-MS Operating Manual

Werbung