Statutory regulations governing installation
5.3.3 Fuel supply
5.3.3.1 The fuel filler must not be situated in the passenger compart-
ment and must be provided with an effective cap to prevent fuel spillage.
5.3.3.2 In the case of liquid fuel heaters, where a supply separate from
that of the vehicle is provided, the type of fuel and its filler point must be
clearly labelled.
5.3.3.3 A notice, indicating that the heater must be shut down before
refuelling, must be affixed to the fuelling point. In addition a suitable
instruction must be included in the manufacturer's operating manual.
5.3.4 Exhaust system
5.3.4.1 The exhaust outlet must be located so as to prevent emissions
from entering the vehicle through ventilators, heated air inlets or opening
windows.
5.3.5 Combustion air inlet
5.3.5.1 The air for the combustion chamber of the heater must not be
drawn from the passenger compartment of the vehicle.
5.3.5.2 The air inlet must be so positioned or guarded that blocking by
rubbish or luggage is unlikely.
(...)
5.3.8 Automatic control of the heating system
5.3.8.1 The heating system must be switched off automatically and the
supply of fuel must be stopped within five seconds when the vehicle's
engine stops running. If a manual device is already activated, the hea-
ting system can stay in operation.
..."
30
ATTENTION:
Failure to follow the installation instructions and the notes
contained therein will lead to all liability being refused by Valeo.
The same applies if repairs are carried out incorrectly or with the
use of parts other than genuine spare parts.
This will result in the expiry of the ECE type approval of the heater
and thus the general operating permit.
Warning!
At petrol stations and other fuel filling facilities the heater must be
switched off due to the explosion hazard. To advice to this requi-
rement the self-adhesive label with the text ''Switch off heater befo-
re refueling!", delivered with each heater, is to be affixed next to the
filler neck.