The exhaust extraction hose in this 2 cycle set is
made of silicon. However, exhaust extraction hoses
made of silicon and activated carbon filter can only be
used for CO measurements, not for HC and Lambda
measurements.
Fig. 2:
AMM with 2 cycle set 687 001 283 to measure exhausts
in 2 cycle engines
1 Silicon exhaust extraction hose 7.5 m
2 Activated carbon filter
3 GF1 rough filter
4 Viton exhaust extraction hose 30 cm
5 Exhaust extraction probe
i
Any possible deposits can quickly be removed after
measurements by blowing out the removed hose
with compressed air.
Robert Bosch GmbH
Downloaded from
www.Manualslib.com
5
4
3
2
manuals search engine
4.

Operation

!
Only transport the BEA 060 in an upright position.
If the BEA 060 is tilted during transportation, con-
densate may escape and damage the measurement
chamber. Select the installation location such that
the BEA 060 cannot fall down and is correctly posi-
tioned (carrying handle at top).
4.1

Power supply

The power supply is obtained from the lighting system.
The BEA 060 can be operated at between 100 V and
240 V, 50/60 Hz.
i
The BEA 060 can also be supplied with power by
way of the vehicle battery using the cigarette lighter
socket connecting cable (special accessory).
Refer to Fig. 1, Pos. 12 for connection.
!
Prior to start-up, make sure the lighting system
1
voltage coincides with the set BEA 060 voltage. If the
BEA 060 is operated outdoors, it is advisable to use
a voltage source protected by a residual current-ope-
rated circuit breaker. The unit is only to be operated
in dry conditions.
!
To avoid the formation of condensation, allow the
BEA 060 to adjust to ambient temperature before
switching on the BEA 060.
i
The details of the power supply are given on
a sticker on the back of the BEA 060.
4.2

Switching unit on / off

4.2.1

Switch-on

1. Plug in the power cord at the BEA 060 and attach
the power cord at the holes (Fig. 1, Pos. 4) with
a cable tie to provide strain relief.
2. Connect the BEA 060 to the lighting system by way
of the power cord.
3. Press the On/Off button.
"
Alternate orange and green flashing of LED
(Fig. 1, Pos. 16).
4.2.2

Switch-off

To keep contamination of the BEA 060 to a minimum,
it is advisable to flush residual gas out of the BEA 060
prior to switch-off with the pump running. The sampling
probe must be in the open air for this purpose.
i
First exit from the exhaust gas test step and wait for
completion of pump run-on. Then switch off the BEA 060.
Press the On/Off button for three seconds.
"
The LED (Fig. 1, Pos. 16) goes out, the BEA 060 is
switched off.
Operation | BEA ��� | 2�
|
1 689 989 112
2012-11-26